Human factors in the medical device industry


There has been a growing emphasis on human factors as a part of the product development process in the medical device industry, in the past few years. In fact, the human factors and ergonomics society even conducted a special symposium on human factors and health care, wherein medical device design was a special track. So, why the sudden demand for human factors in the medical device industry? A lot of this demand is driven by regulatory requirements and I attempt to describe some of this in this blog.

Several medical device directive (MDD) and active implantable medical device (AIMD) changes took place in 2010. This impacted multiple functions (e.g., Regulatory, risk management, technical communications) and had an effect on legacy, ongoing, and future products. For example, the crux of the MDD changes included:
  • Designing and manufacturing medical devices in such a way that when used under the conditions and for the purposes intended, they will not compromise the clinical condition or the safety of patients, or the safety and health of users.
  • Reducing the risk of use error due to the ergonomic features of the device and the environment in which the device is intended to be used.
  • Considering the technical knowledge, experience, education and training and where applicable the medical and physical conditions of intended users.
In summary, essential requirements related to human factors and ergonomics was added to MDD and AIMD.  As part of the MDD/AIMD work, two human factors engineering standards, EN 60601-1-6:2007 and EN 62366:2008 were harmonized and was in effect.

 So, what is EN 62366? 
  • This is a ‘process standard’, that tells a manufacturer the process to  analyze, specify, design, verify and validate usability, as it relates to the safety of a medical device.
  • The standard focuses on the need to provide adequate usability such that the “risks resulting from normal use and use error are acceptable”.
  • The standard focuses on identifying and mitigating design-induced use error.
  • The standard discusses the need to validate primary operating functions.
  • Overall, this standard emphasizes a more formal human factors process that combines analytical and empirical methods to detect as well as mitigate use error.
  • The standard also requires the maintenance of a usability engineering file and associated documentation that human factors work was done. However, the process is scalable.

In 2011, FDA published a draft guidance on “Applying Human Factors and Usability Engineering to Optimize Medical Device Design” for comment purposes. The comment period is complete but the effectivity date for the guidance is still TBD. Overall the FDA draft guidance is very similar to EN62366.  However, some key differences exist:
  • The FDA draft guidance focuses on using analytical and empirical methods very early in the project lifecycle to identify and mitigate sources of use error.
  • There are clear expectations for handling, documenting, and resolving use errors.
  • The guidance discusses a human factors engineering summary report, which is very elaborate and prescriptive.
As a human factors advocate, I believe that irrespective of the regulatory driven requirements, human factors should be an integral part of the product development lifecycle in medical device industries (or any industry) so as to create products that are not only safe but also improve user workflow and efficiency.  

6 comments:

  1. A Medical Device Master File is a submission to U.S. FDA that may be used in support of premarket submissions to provide confidential detailed information about establishments, processes, or articles used in the manufacturing, processing, packaging, and storing of one or more medical devices. Registrar Corp's team of medical device regulatory experts provides guidance as to required elements, formats, and particularities of Medical Device Master File submissions. For assistance submitting a Medical Device Master File, simply click the Medical Device Master File Certificate shown on the left.

    ReplyDelete
  2. A combination of human factors and robotics is sure to be the future of medicine as we continue to pursue the greatest level of efficiency.

    ReplyDelete
  3. "This may sound like it is out of a science fiction movie, but the threat is conceivably a serious one," said Jon Ogg at 24/7 Wall Street.submission

    ReplyDelete
  4. Hi Arathi,
    I'm writing an education article for the device industry publication "The Silver Sheet" about formative testing as it relates to FDA's 2011 human factors draft guidance.
    Please get in touch with me ASAP if you'd be willing to briefly chat.
    Thank you!
    Shawn Schmitt (sm.schmitt@elsevier.com)
    Managing Editor

    ReplyDelete
  5. This article was very helpful for me to know the human factors in the industry of medical device with detailed information.
    Web Designing Companies | Webs Design Companies

    ReplyDelete
  6. This is a great inspiring article.I am pretty much pleased with your good work.You put really very helpful information... smart mobile broadband bandwidth

    ReplyDelete